ISO 12543-2-2011 pdf free download.Glass in building — Laminated glass and laminated safety glass — Part 2:
Laminated safety glass
Verre dans la construction — Verre feullieté et verre feullieté de sécurité — Partie 2: Verre feullieté de sécunté.
accordance with ISO 12543-4:2011, 5.4. No fault (i.e. bubbles, delamination, haze or cloudiness) shall be found in three test specimens,
If faults are found in only one test specimen, three new test specimens shall be tested in accordance with ISO 125434:2011, 5.3.2, and evaluated in accordance with ISO 125434:2011, 5.4. No fault shall be found in any of these three test specimens.
5.1.3 Laminated safety glass that includes plastic glazing materials andlor encapsulated material
Laminated safety glass shall be tested in accordance with ISO 12543-4:2011, 5.3.3, and evaluated in accordance with ISO 12543-4:2011, 5.4. No fault (i.e. bubbles, delamination, haze or cloudiness) shall be found in three test specimens.
If faults are found in only one test specimen, three new test specimens shall be tested in accordance with ISO 125434:2011, 5.3.3, and evaluated in accordance with ISO 125434:2011,5.4. No fault shall be found in any of these three test specimens.
5.2 Humidity test
Laminated safety glass shall be tested in accordance with ISO 125434:2011, 6.3.1, and evaluated in accordance with ISO 125434:2011, 6.4. No fault (i.e. bubbles, delamination, haze or cloudiness) shall be found in three test specimens.
If faults are found in only one test specimen, three new test specimens shall be tested in accordance with ISO 125434:2011, 6.3.1, and evaluated in accordance with ISO 125434:2011. 6.4. No fault shall be found in any of these three test specimens.
5.3 Radiation test
Laminated safety glass shall be tested in accordance with ISO 125434:2011. Clause 7, and evaluated in accordance with ISO 12543-4:2011, 7.5.1. The luminous transmittance of three irradiated test specimens shall not change by more than
a) ±3 % of their value before exposure for initial light transmittances of greater than 65 %, or
b) ±2 % of their absolute value for initial light transmittances of less than or equal to 65 %.
When visually inspected, no fault (i.e. bubbles, delamination, haze or cloudiness) shall be found in the three irradiated test specimens.
If faults are found in only one test specimen, three new test specimens shall be tested in accordance with ISO 125434:2011, Clause 7. and evaluated in accordance with ISO 12543-4:2011, 7.5.1. No fault shall be found in any of these three test specimens.ISO 12543-2-2011 pdf free download.
All resources on this website are from the Internet. It is only for personal study and research. No one is allowed to use it for any commercial purpose. If you need, please buy the genuine standard. If there is any infringement of your copyright, please contact the webmaster in time, and I will correct it immediately.
- Maybe you like
- More
- Latest Updates
- ISO 287-2009 pdf free download
- ISO 527-5-2009 pdf free download
- ISO 659-2009 pdf free download
- ISO 660-2009 pdf free download
- ISO 712-2009 pdf free download
- ISO 725-2009 pdf free download
- ISO 730-2009 pdf free download
- ISO 927-2009 pdf free download
- ISO 2041-2009 pdf free download
- ISO 3040-2009 pdf free download
- ISO 3506-2-2009 pdf free download
- ISO 3506-3-2009 pdf free download