UL 15027-2-2020 pdf free download.Immersion suits – Part 2 : Abandonment Suits , Requirements Including Safety.
A passive light system of retrorefiective material shall be provided. This shall conform to the specification detailed in IMO Resolution A.658(16), Annex 2. If it is the only light system. then a total area of not less than 400 cm2 shall be provided. At least 100 cm2 shall be affixed to the hood and in addition at least 250 cm2 shall be clear of the water and visible in the suit’s normal in water position as tested in ISO 15027. 3:2012, 3.10.6.4.1. At least one piece of 50 cm2 shall be affixed to the back of the suit.
4.5.2DV.1 D2 Modification of clause 4.5.2 by revising first paragraph as follows:
A passive light system of retro-reflective material shall be provided. This shall conform to the specification detailed in MO Resolution A.658 (16), Annex 2. If it is the only light system, then a total area of not less than 400 cm’ shall be provided of which:
• At least 50 cm’ shall be affixed to the hood and
• At least 200 cm’ shall be clear of the water and visible In the suit’s normal in water position as tested in ISO 15027-3:2012, 3.10.6.4.1, and
• At teast 100 cm2 shall be clear of the water and visible when the subject is lying face down In the water, and
• At least 25 cm’ shall be located on each forearm.
The performance of the retro-refiective material shall not be degraded by the method used to apply it to the suit. Test in accordance with ISO 15027-3:2012. 3.10,6.4.2.
An active light system shall be provided if the abandonment suit is intended to be used without a PFD. An active light system may be provided if the abandonment suit is intended to be used with a PFD. The active light system shall conform to the standard for emergency lights in ISO 12402-8. When an active light system is provided, the area covered by the passive light system may be reduced, but a minimum of 300 cm2 of the passive light system should always be provided. At least 100 cm2 of which should be affixed to the hood and 150 cm2 clear of the water and visible in the suit’s normal in water position as tested in ISO 15027-3:2012, 3.10.6.4. At least one piece of 50cm2 shall be affixed to the back of the suit.
4.5.2DV.2 D2 Modification of clause 4.5.2 by revising third paragraph as follows:
An active light system shall be provided on the abandonment suit. The light shall be placed in a location that ensures it is effectual and does not impede the user’s mobility. The active light system shall conform to the standard for emergency lights in ISO 12402-8.UL 15027-2-2020 pdf free download.
All resources on this website are from the Internet. It is only for personal study and research. No one is allowed to use it for any commercial purpose. If you need, please buy the genuine standard. If there is any infringement of your copyright, please contact the webmaster in time, and I will correct it immediately.
- Maybe you like
- More
- Latest Updates
- ISO 287-2009 pdf free download
- ISO 527-5-2009 pdf free download
- ISO 659-2009 pdf free download
- ISO 660-2009 pdf free download
- ISO 712-2009 pdf free download
- ISO 725-2009 pdf free download
- ISO 730-2009 pdf free download
- ISO 927-2009 pdf free download
- ISO 2041-2009 pdf free download
- ISO 3040-2009 pdf free download
- ISO 3506-2-2009 pdf free download
- ISO 3506-3-2009 pdf free download