UL 355-2020 pdf free download.Cord Reels.
16.3 A cord reel not intended for permanent mounting shall be provided with an attachment plug assembled to the power-supply cord.
16.4 A cord reel not provided with a flexible cord for connection of the load shall be provided with wiring terminals for cord connection, The wiring terminals shall be capable of accommodating conductors of the size recommended by the manufacturer for use with the reel, and the wiring terminals shall comply with the requirements in 16.9 and 16.11 — 16.16.
16.5 A terminal intended for the connection of a grounded supply conductor shall be:
a) Identified by a plating substantially white in color (such as nickel),
b) Of a metal that is substantially white in color, or
C) Otherwise be colored white, marked WH.” or proper identification of the terminal shall be clearly
shown in some other manner, such as on an attached wiring diagram.
16.6 The field wiring lead, or the conductor of a jacketed cord, intended for the connection of the grounded supply conductor shall be identified by:
a) White or gray colored conductor insulation or
b) Light blue colored conductor insulation with the insulation of the other conductors having colors
other than white or gray.
16.7 The conductor of a parallel cord intended for the connection of the grounded supply conductor shall be identified by:
a) A continuous rib or ribs running the length of the cord or b) Tinned or white metal on all strands of the conductor.
16.8 If a cord reel is intended for mounting on an outlet box, wiring terminals that will be inside the box after the reel is installed shall be located or recessed so that contact will not occur between the terminals and the wires inside the box after the reel is installed.
16.9 A wiring terminal shall be mounted so that the terminal will not turn or shift in position. Friction between surfaces is not acceptable as the sole means to prevent the turning of a wiring terminal.
16.10 A wiring terminal shall be capable of securing a conductor having an ampacity not less than the maximum current rating of the reel, but not smaller than 14 AWG (2.1 mm²).UL 355-2020 pdf free download.

Download Information
Go To Download

All resources on this website are from the Internet. It is only for personal study and research. No one is allowed to use it for any commercial purpose. If you need, please buy the genuine standard. If there is any infringement of your copyright, please contact the webmaster in time, and I will correct it immediately.