Position:Home>UL Standards>UL 60320-1-2019 pdf free download

UL 60320-1-2019 pdf free download

UL 60320-1-2019 pdf free download.Appliance Couplers for Household and Similar General Purposes-Part 1 : General Requirements.
12.1 DV Dl Modify Clause 12.1 by deleting the first paragraph.
I 2.2DV Dl Modify Clause 12.2 by replacing the first paragraph with the following:
Rewirable appliance couplers shall be provided with screws and nuts for clamping the conductors that shall have either a metric ISO thread or an ANSI Unified Screw Thread.
I 3.2DV.1 Dl Modify Clause 13.2 by replacing the first paragraph with the following:
In non-reversible connectorslplug connectors, the contact positions shall be established by looking at the engagement face of the connectorslplug connectors as shown in the standard sheets overview in Clause 4 of CSA-C22.2 No. 60320-3IUL 60320-3.
13.2DV.2 Dl Modify Clause 13.2 by replacing the third paragraph with the following:
In non-reversible appliance couplers which do not comply with the standard sheets shown in the overview of Clause 4 of CSA-C22.2 No. 60320-3IUL 60320-3, the correct polarization shall be verified.
I 3.5DV Dl Modify Clause 13.5 by replacing the second paragraph with the following:
For connectorslappliance outlets, self-adjustment of the contacts shall not depend upon the resiliency of insulating material.
I 3.8.2DV Dl Modify Clause 13.8.2 by replacing the first paragraph with the following:
A length of 6 mm of Insulation Is removed from the end of a 18 AWG stranded conductor. One wire of the flexible conductor shall be left free and the remaInIng wires shall be fully inserted into and clamped in the terminal, as for normal use.
13.90V Dl Delete Clause 13.9:
Clause 13.9 does not apply.
13.IODV Dl Modify Clause 13.10 by replacing it with the following:
Fuses, relays, thermostats, and thermal cut-outs shall not be incorporated in connectors and plug connectors complying with the standard sheets of CSA-C22.2 No. 60320-31 UL
60320-3.
Fuses, relays, thermostats and thermal cut-outs incorporated in appliance inlets and appliance outlets shall comply with the relevant UL and/or CSA standard.
An inlet with an integral supplementary protector (fuse) shall comply with the fuseholder temperature test described In UL 498.
Switches incorporated in appliance couplers shall comply with UL 61058-1 or CANICSAC22.2 No. 61058-1, UL 61058-1-1 or CANICSA-C22.2 No. 61058-1-1, UL 61058-1-2 or CAN! CSA-C22.2 No. 61058-1-2, as applicable.
Energy regulators Incorporated In appliance couplers shall comply with CAN/CSA-E60730- 2-11!UL 60730-2-11 or CSA-C22.2 No. 24/UL 873.
Compliance shall be checked by inspection and by testing the switches, fuses, relays, thermostats, thermal cut-outs, and energy regulators according to the relevant North American standard.
Table 2DV Dl Delete Table 2:
This table is not applicable.
15.1 DV.1 Dl Modify Clause 15.1 by replacing item (k) with the following:
k) for rewirable connectors between any metal part of the cord anchorage, excluding clamping screws, and a metal rod of the maximum diameter of the largest flexible cord type as specified by the manufacturer.
15.IDV.2 Dl Modify Clause 15.1 by replacing item (m) with the following:
m) for rewirable plug connectors, between any metal part of the cord anchorage, excluding clamping screws, and a metal rod of the maximum diameter of the largest flexible cord type as specified by the manufacturer.UL 60320-1-2019 pdf free download.

Download Information
Go To Download

All resources on this website are from the Internet. It is only for personal study and research. No one is allowed to use it for any commercial purpose. If you need, please buy the genuine standard. If there is any infringement of your copyright, please contact the webmaster in time, and I will correct it immediately.