Position:Home>AS Standards>AS 5159.1-2018 pdf free download

AS 5159.1-2018 pdf free download

AS 5159.1-2018 pdf free download.Trampoline park facilities Part 1 : General safety requirements and test methods.
2.8.2 Specific requirements for impact altenualion
2.8.2.1 Impact attenuating system surrounding a trampoline, device, horizontal suiface within the impact area and landing (parLour) bar
The surface of the potential impact area shall be covered with an impact attenuating system that limits the value to less than 200g and the 1-1K’ to less than 1000, and with an impact event duration of greater than 5 rn.s at a nominated fall height of 1.5 rn
NOTES:
I This level of impact attenuation may not prevent serious injury.
2 Examples of impact attenuating systems known to provide these impact-attenuating properties are 50mm thick ethylene-vinyl acetate (EVA) foam with a density of 45 kg/rn’.
2.8.2.2 Impact aI:eiuialing system for vertical surface
Vertical surfaces within the impact area, with the exception of high performance walls and parkour box walls, shall be covered with an impact attenuating system that limits the g, value to less than 200g and the Hl(’ to less than 1000 and with an impact event duration of greater than 5 ms at a nominated fall height of 1.5 m.
2.8.2.3 Impact arrenuaring system surrounding a high performance trampoline
The surface of the potential impact area shall be covered with an impact attenuating system that limits the g1 value to less than 200g and the 1-1K’ to less than 1000 and with an impact event duration of greater than 5 ms at a norninatd fall height of 4.0 m.
2.9 FREE SPACE
2.9.1 (;cneral
The free space shall not contain items likely to be a hazard in the case of an impact, e.g. walls not designed for trampolining activities, glass windows, sprinklers, lights. Cxii signs, stored items or other physical structures.
2.9.2 Extent of free space
The extent of free space shall be determined as part of the risk and hazard assessment by a competent person.
hard surfaces of jumping (parkour) boxes, high performance walls and similar structures are exempt from free space requirements.
To prevent patrons contacting overhead hazards there shall be a minimum clearance of 4 m in general areas and 6 m in high performance trampoline areas when measured perpendicular from the trampoline bed. This free space shall have no suspended or protruding objects such as lights or sprinkler heads.AS 5159.1-2018 pdf free download.

Download Information
Go To Download

All resources on this website are from the Internet. It is only for personal study and research. No one is allowed to use it for any commercial purpose. If you need, please buy the genuine standard. If there is any infringement of your copyright, please contact the webmaster in time, and I will correct it immediately.